Service

Change Search Parameters

Select Searchorder

Select Country

Austria Belgium Bulgaria Cyprus Czech Republic Germany Denmark Estonia Spain Finland France United Kingdom Greece Hungary Ireland Italy Malta Netherlands Lithuania Luxemburg Lativia Poland Portugal Romania Sweden Slovenia Slovakia
AT
BE
BG
CY
CZ
DE
DK
EE
ES
FI
FR
GB
GR
HU
IE
IT
MT
NL
LT
LU
LV
PL
PT
RO
SE
SI
SK

Select Hot Topics

Financing and Management

Funding Incentives Project Management Asset Management

Knowledge and Support

Partnership Working Work with Residents Capacity Building

Architecture

Thermal Insulation Windows and Shading Air Tightness Environmental Design

Renewable Energies

Solar Thermal Solar Photovoltaic Other Renewables

Building Services

Heating and Hot Water Cooling Ventilation Electricity Saving Products Water Saving

Monitoring and Certification

Certification Monitoring

Select Type of Project

Construction Refurbishment Other

Case Study: Dole: Rehabilitation Low consumption of 36 housing

Name of organisation: SA-Doloise du Jura

Stage of development:

Year of finalization: 0

Type of project:

Area:

Scale:

Type of building:

Number of units/dwellings: 122

Tenure:

Street: 5, Rue Bougauld

Postcode: 39100

City: Dole

Region/ County:

Country: France

Last Update: 11.07.2011

Short Description

Condition before the work:

The condition of the building was the following:

Loss of the building "Isolation"
- Need for energy flux: 83 000 or 180 W / m²
- After isolation: 28 000 or 60 W / m²

Heating:
- Requirements state: 166 kilowatts
- After isolation: 57 kW

Ventilation:
- A breakdown in the presence of uncontrolled non-compliant with current regulations. Very uncomfortable especially for renters with external joinery facilities if emphasized the thermal discomfort.

General appearance of homes:
- General deterioration mainly due to poor insulation and poor ventilation;
- Amplified presence of mold in the building;
- The embellishments are faded and a cover of soil is difficult;
- Landing doors to lock single point of thinness does not guarantee a comfortable tone and are not effective enough in terms of air tightness and resistance to fire.

Insecure Gas:
- Unventilated technical gain
- Old doorless taps

Electricity:
- Public installation outdated and not secure.
- Installation in basic unsafe accommodation.
- Very few outlets in each unit that requires the use of multi taken outlets.
- Non-compliance with RT 2005.

What steps have been taken?

Here are the steps energy retrofitting links:
- Change exterior joinery
- Partitions attics and cellars
- Intervention to remove the balcony decks
- Double glazed with Gas
- Millwork: air tightness
- Insulation basement slab high mineral fiber
- Insulation wool slab low attic
- Installation of thermostats and thermostatic canes
- Condensing boilers individual
- Ventilation: HRV collective flow
- Ventilation: Air tightness of dwellings
- Thermostatic valve for showers

Key Elements

Main Results

What level of energy performance has been achieved?

Consumption before the work: 333 WhEP/m2. year

Consumption after work:

Lessons learned

Calculating the return of investment?

Please download HERE the Financial Plan.

Additional Information

How social housing organizations manage the investment risk?

One of these three devices allows social housing organizations to spread the cost of improvements in energy performance between landlords and tenants:

 

- The rent increase within the rent ceiling?

- Use a third line on the receipt of tenants

- An increase in rent under the conventional social utility.

Related Files